Gerhardt Extraction Systems
|
Soxtherm
Automatic rapid extraction systems
Controlling up to 4 units
For many years, Gerhardt has been a successful manufacturer of the automated rapid Soxhlet systems Soxtherm. Thanks to the close relationship with our customers and partners worldwide, this highly successful instrument has been improved further.
Depending on the size of the laboratory and the sample throughput, the customer now has the option of a 2, 4, or 6 place system. The controller, Multistat, can control and monitor up to 4 units individually. The savings in costs and space are tremendous. The fully automated process ensures highest precision for minimum input.
The solid-liquid extraction according to Soxhlet and Twisselmann can be done much more efficiently by using these systems. Thus, the Soxtherm simplifies and accelerates the traditional Soxhlet method in key areas. The extraction has up to five programmable stages. The patented process is fully automatic and is especially useful for the determination of fat and for residue analysis.
|


|
- 3 units available giving the widest range of options for all laboratories
- Solvent recovery reduces running costs
- Water and compressed air control give unattended operation and saves water making the system environmentally friendly
- Fast and accurate giving an increased sample throughput compared to the traditional Soxhlet
- Capable of being used with all solvents giving flexibility of applications
- Fully programmable with automatic start-up and shut down for unattended operation
- Low solvent usage reduces running costs
- Only 3 moving parts and no internal seals means no routine maintenance is required
- Large thimbles available for large sample sizes
- Single button operation for ease of use
- One Multistat controls up to 4 units which gives lower cost upgrades
Safety features
- Cooling water and air monitoring
- Safety door protects the operator from hot surfaces
- Over temperature cut-out prevents flash point of the solvent being exceeded
- Optical sensor on solvent recovery tank prevents over filling
- Acoustic and visual warnings inform operator of system problems
- Spark proof heaters to DIN/VDE 0170 and 0171 meet the high standards required
- Illuminated glass beakers allow easy visual inspection of extraction progress
Fat Determination with Soxtherm
Almost all food contains fat. When working with the Gerhardt Soxtherm, the determination of the fat content in food and feeds is simple, fast, and reliable.
Cereals and cereal products
- Milk and dairy products
- Meat and meat products
- Chocolate and cacao products
- Oil and oilseeds
- Fruits
- Fat in feed
- Lipids in egg and egg products
- Sample Preparation with Soxtherm
Soxtherm is a very precise instrument when it comes to the determination of the pollution of e.g. soil or water. The data obtained can then be used to make fast environmental decisions.
- Mineral oil in rocks
- Oil and lubricants
- Pesticides
- Phenoles (PCB)
- Dioxine
- EOX - Extractable organic halides
- Plasticisers and additives in plastics and rubber
- Fibre and textile coatings
- Explosives in residual waste
- Coatings of fertilizers
- PAH - Poly aromatic hydrocarbons
PC-Software for Rapid extraction
You can individually control and monitor up to 4 Soxtherm extraction units type S4 using a PC. All functions, which are already well known from the controller Multistat, are integrated into the program. Furthermore, multiple documentation - and logging options, like e.g. the sample name, program and recognition of the user are offered as well.
With the introduction of the Soxtherm-Manager, Gerhardt now offers an efficient software, which meets all the demands of a modern laboratory management.
- Control of up to 4 Soxtherm basic units
- Monitoring of the Soxtherm basic units
- Programming and storage of the extraction programs
- Logging and documentation of all relevant data
- Diagnosis function for an ideal extraction process
- Concise arrangement of all relevant status displays in separate windows facilitates the best possible supervision
- Clearly structured program windows
- Each Soxtherm unit has a program window and a status window. At any given time, the user has a perfect overview of all functions andprograms in use. Up to 4 Soxtherm units are displayed at one screen.
|
|
|
Traditional extraction systems
Extraction system for extractions according to Soxhlet, Twisselmann and other techniques. If a fully automated rapid extraction process is required or if highly flammable solvents are used please ask for or take a look at Soxtherm.
Extraction Heating Unit
Serial heating unit EV 14 or EV 16 for 4 or 6 extractions for flasks of 250 - 500 ml using the classical Soxhlet method. Supplied with top moulds, air bath inserts, support rods (600 mm x 12 mm) and power cord. Not included are cooling water feed pipe, Soxhlet glass parts, and holder.
|

|
|
|
|
Fibretherm - Crude fibre / ADF / NDF
Automated Crude Fibre Determination
Based on the established Gerhardt FibreBag Method, the new Fibretherm offers the fully automated processing of the tedious boiling and filtration steps for the crude fibre-, ADF- and NDF-determination. Fibretherm has many advantages compared to the standard method. Up to 12 samples can be digested and filtrated simultaneously, which saves precious bench space as well as chemicals. The savings are especially significantfor labs with a high sample throughput. The procedure with controlled boiling steps as well as the unique, highly precise filtration mesh of the FibreBags ensure highly precise results. The entire process takes place in a closed system.
|

|
FibreBag-Method
Up to 12 samples are each weighted into a Fibre Bag. Just like in the traditional method, the required boiling times and filtration steps are done for all samples simultaneously. When determining the crude fibre content, the non soluble contents as sulfuric acid and caustic potash solution remain in the Fibre Bag. The residue is dried, weighted and then incincerated. The difference between the ash content and the non-diluted residue in relation to the initial sample weight, is the crude fibre content. When doing an ADF- and NDF-determination, the sample is treated with the respective detergents, the remaining substances of the cell structure are specified and determined according to this method as well. Also the calculation is done identically to the crude fibre determination.Since all analyses are conventional methods, it is very important to observe the respective times for the boiling procedures as well as observing the weighing procedures as exactly as possible.
Save time:
- Simultaneous analysis of up to 12 samples
- Quick and safe filtration
- Short heating up time
Ergonomic features:
- Small footprint - saves bench space
- Easy cleaning
- Safe operation
- Storage of up to 10 methods
- Use of inert materials - prevents corrosion
Reduce the costs:
- Automation of procedure
- Saves chemicals thus saves as well the costs forwaste disposal
- Monitors cooling water and energy
Optimizes the quality of the analysis:
- Automated reproducible conditions of analysis
- Constant filtration quality of FibreBags
- Low blank values due to almost complete incineration
|
|
|
FibreBag®/crude fibre /Hydrolysis
FibreBag Systems for crude fibre-, ADF- and NDF-determination
acc. to LEPPER, VAN SOEST, WEENDER a.o.
The introduction of the revolutionary FibreBag System by Gerhardt means that the tedious and time-consuming stages usually associated with this determination process like e.g. Weender, van Soest and others, can be reduced to a minimum. Space as well as the consumption of energy and chemicals is reduced to a sixth of the traditional methods. At the same time the conformity to the methods is maintained.Gerhardt offers 3 systems for a special package price. For low sample throughput we recommend the basic pack for up to 6 samples simultaneously. For high sample throughput we recommend the 24-place or the 36-place system, with serial heating plates. All system components can also be ordered individually
|

|
Crude Fibre digestion system
Serial heating unit EV 14 or EV 16, can be used for 4 or 6 crude fibre digestions acc. to Lepper. Supplied ready for use with special supports, glass condensers, ring shaped rest, silicone rubber tubings, beakers (1000 ml), and power cord.
Hydrolysis
Consists of the crude fibre digestion unit RF 16/6 plus a filter insert with 6 funnels DIN 12445, 100 mm, 1 soft polyethylene bottle with a narrow mouth (1000 ml), 100 folded filters as well as 250 g boiling stones. Supplied with special supports, glass condensers, ring shaped rest, silicone rubber tubings, beakers (1000ml), and power cord.
For further information on this product please contact the product manager, Jamie Duncan on 01342 820820 or email enquiries@qclscientific.com.